1) Voltage (V) means the motor in normal
operation, the stator windings to be connected to the supply voltage. different
countries and regions use a lot of different voltage, so the motor voltage
specifications are also many, such as: 120V, 230V, 220V, 240V, 100V, etc., is
also useful in industrial applications, 12V, 24V, 36V, 45V and so on. Supply
voltage tolerance of not more than ± 5%.
2) Frequency (Hz) is the frequency of the
AC power, China's power grid frequency is defined as 50 Hz, some country use 60
Hz. Frequency allows the deviation does not exceed ± 1%.
3) Power (W) means the motor is running at
rated mechanical shaft output power.
Our company's (Ningbo Jant Electrical Appliance c Ltd.,)motor
nameplate rated power generally refers to the maximum input power.
4) Speed (RPM) indicates the motor at the rated voltage, frequency
and output power to run the rotation speed. Typically, the motor speed is the
speed of the motor shaft(no load), for some specialty products is often
expressed through the output gear of the actual rotational speed of the shaft(on
load), shaded pole motor speed is lower than the power supply frequency and
Electric poles synchronous speed determined.
5) Current (A) refers to the motor is
running at rated conditions stator windings of the input current can be used to
check whether the motor is overloaded or defective.
6) Efficiency (η) means the motor is
running at rated output power and input power ratio. Generally in the motor to
reach thermal steady state, with a dynamometer directly measured the output
torque and rated speed records to calculate the output power, while the motor
power input is read directly from the test instrument.
7) Insulation class indicates the motor
winding insulation level for determining the allowable temperature rise of the
motor, commonly used insulation levels are A, E, B, F, and H five, corresponding
to the maximum operating temperature of 105 ℃ ,
120 ℃ , 130 ℃ ,
155 ℃ and 180 ℃ .
8) Some other indicators have been
specially designed or special use of the motor, but also marked on the
nameplate on the technical indicators, such as work methods (continuous,
short-term, intermittent cycle operation), the thermal protection in the form
(impedance protection, disposable thermal Insurance protection, etc.), power
factor, starting current and torque overload factor and so on